Materials science is at the heart of innovation, shaping the tools and technologies of our modern world. Let's dive into the intricacies behind the materials that define the music and sounds of our lives.

11/21/2026 ⋅ By Rishi Pai ⋅ 6 min read

What It Takes to Make Electronics Stick to Skin

Fingerprints_close-up.jpg

Try wrapping a flat piece of tape around the tip of your index finger. It goes on smoothly down the middle, but as you press it around the sides, the tape starts to bunch up. Now imagine that the tape is supposed to pick up the tiny electrical signals from a muscle. Suddenly, those wrinkles are an engineering problem.

​

The same problem comes up in epidermal electronics, devices designed to sit directly on the skin. We tend to judge a wearable by what it can measure. I want to start one step earlier. What has to happen where the device meets your skin for the measurement to work? [2, 3]

​

Why build a sensor on a fingertip?

​

In 2017, Akihito Miyamoto and colleagues made a wearable electrode from a gold mesh. They coated a web of polymer fibers with gold, then dissolved the fibers away with water once the mesh was on the skin. In their tests, water vapor passed through the mesh more readily than through the thin plastic film and rubber sheet they tested. The University of Tokyo reports that the researchers saw no clear signs of skin inflammation with the mesh in a one-week patch test involving 20 people. The team also used the electrode to record electrical signals from muscles. [1]

​

A November 2026 study by Xiaoping Liang and colleagues took the mesh idea in a new direction. The team used electrospinning, a method that draws fine fibers out of a liquid with an electrical field to build the mesh right on the skin. The researchers reported making conductive fibers less than 1 micrometer across from a mixture containing carbon nanotubes. On a fingertip, the resulting mesh followed the fingerprint ridges. The plastic film the researchers applied for comparison wrinkled. [2]

​

One of the team's demonstrations was a pressure sensor built right on the fingertip. It had two conductive meshes with a thin compressible layer in between. Press on the sensor, and the middle layer gets thinner, moving the two meshes closer together. That increases the sensor's capacitance, so it can store more charge at the same voltage. The team recorded those changes in capacitance as a wearer grasped objects. [2]

​

The trouble with sticky pads

​

Some pads for an electrocardiogram (ECG) use a hydrogel, a material that holds a lot of water. Dissolved salt supplies ions that can carry charge through the gel, helping the electrode pick up the small changes in voltage that come from your heartbeat. The connection can get worse as the gel dries out. A gel that lets little water vapor through can also leave sweat trapped against your skin. How do you keep the gel wet while still giving water vapor a way out? [3]

​

Jun Ma and his colleagues started with a mesh of poly-lactic acid fibers and coated it with a salty hydrogel. The microscope image makes the idea easier to see. You can still make out the individual strands beneath the coating. The gel follows the shape of the fibers and leaves little gaps between them for vapor to pass through. [3]

​

One test looked a lot like an ordinary afternoon. The team recorded an ECG for about 2.5 hours straight while the wearer worked at a computer, rested, and walked. In a separate test, the team reported that by day 30, the mesh electrode signal-to-noise ratio was still above 25 dB. The commercial gel electrodes used for comparison were at 18 dB. In plain terms, the heart electrical signals stood out more clearly from the background noise with the mesh. [3]

​

When a fainter line means more

​

What if you're sitting at a desk when it's time to take a sweat sample? Soongwon Cho and his colleagues use a small electric current to deliver a compound called carbachol through the skin and stimulate the sweat glands. Narrow paper channels then carry the samples to separate test strips. The team was looking for cortisol, a hormone whose levels change throughout the day and can rise when you're under stress. [4]

​

Here's a part I like. In the team's calibration test, the more cortisol they put in the sample, the fainter the test line became. The color comes from gold nanoflowers, tiny branching particles that carry antibodies capable of binding cortisol. At the test line, the researchers put a protein with cortisol attached to it. When cortisol from the sweat binds to some of the antibodies first, fewer of the gold particles get caught at the line. That's why the color fades. [4]

​

The researchers compared 26 pairs of sweat and saliva measurements from six people. They reported a Pearson correlation of 0.73 across those measurements. In other words, higher cortisol readings in sweat generally went with higher readings in saliva. I'd be curious to see how closely those two readings move together for each person, especially if you follow a larger group over several days. [4]

​

What I’d watch for next

​

What I like about putting these studies side by side is how differently the devices handle moisture. Ma's electrode gives water vapor a way out. Cho's patch collects liquid sweat and guides them to a test strip. In both cases, the material has to manage what happens in the tiny space between the device and the skin. [3,4]

​

I keep coming back to the fingertip. You can see whether a mesh follows a fingerprint in a single image. Finding out whether a device gives you a useful reading at the end of an ordinary day takes a different kind of test. What happens when a sleeve rubs against an electrode for hours? How much do readings vary from one person to the next? I'd like to see what happens when more people take these devices home and simply go about their day. But until dhin . . . stay upbeat, and stay tuned.

​

Sources

  1. Miyamoto, A., Lee, S., Cooray, N. F., et al. “Inflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes.” Nature Nanotechnology 12, 907-913 (2017). DOI: 10.1038/nnano.2017.125. https://pubmed.ncbi.nlm.nih.gov/28737748/ 

  2. Liang, X., Guo, R., Chen, H., et al. “In-situ fabrication of ultra-conformal nanomesh epidermal sensors on arbitrary skin surface.” Nature Communications (2026). DOI: 10.1038/s41467-026-79805-x. https://www.nature.com/articles/s41467-026-79805-x_reference.pdf 

  3. Ma, J., Wang, M., Wang, Y., et al. “A symbiotic skin hydrogel interface enabled by flexible hydrogel network with embedded enhancement structure.” Nature Communications 17, 8528 (2026). DOI: 10.1038/s41467-026-75372-3. https://pmc.ncbi.nlm.nih.gov/articles/PMC13482402/ 

  4. Cho, S., Shajari, S., Xiong, Y., et al. “Wearable lateral flow assays for cortisol monitoring with time-dynamic sweat sampling and sensing by electrochromic timers.” Nature Sensors 1, 85-98 (2026). DOI: 10.1038/s44460-025-000005-z. https://rogersgroup.northwestern.edu/files/2026/natsenscortisol.pdf 